Put the negative on an even daylight-balanced light pad, mount the camera parallel to it with a macro lens, shoot RAW at your camera’s base ISO and f/8, then invert the files in software. Most of the steps below follow the scanning guide from Negative Lab Pro, a commercial conversion plugin for Lightroom.

What you need

  • A camera on a tripod or copy stand.
  • A macro lens. Negative Lab Pro prefers a modern macro lens used natively, not through adapters or tubes. Fstoppers describes shooting at 1:1.
  • A light with a Color Rendering Index (CRI) of at least 90, daylight balanced at 5000 K or 5500 K, with even output.
  • A film carrier that lifts the negative off the light pad. Negative Lab Pro says this prevents Newton rings and keeps the film flat, which matters because macro depth of field is shallow.
  • Something opaque, such as dark paper, to mask stray light around the frame.

Starting settings

SettingStarting point (Negative Lab Pro)
File formatRAW; JPEG and TIFF carry built-in settings that distort color when inverted
ISOBase ISO, usually 100 or 200
Aperturef/8.0, to limit vignetting
ShutterThe meter’s reading, or 1 stop higher to capture more levels from dense areas
ExposureManual, the same for the whole roll
White balanceNot critical when shooting RAW

Source: Negative Lab Pro, “Scanning Guide,” and Fstoppers (Rob Baggs, April 2020), checked November 2026.

Set up and shoot

  1. Wash your hands and handle the strip by its edges. The Library of Congress recommends clean lint-free cotton or nitrile gloves and avoiding contact with the image surface.
  2. Clear dust with a blower such as an air bulb; the Library of Congress says not to use canned air.
  3. Place a mirror on the light pad and move the camera until the lens reflection is centered. Negative Lab Pro uses this to get the camera parallel to the film.
  4. Mask all stray light, including light through the sprocket holes. Negative Lab Pro also says to use a lens hood and remove filters, which can cause reflections.
  5. Focus manually with live view and check that the grain is sharp. Without focus peaking, Negative Lab Pro suggests autofocus on each frame, with some variation in sharpness.
  6. Shoot the roll without changing exposure.

Convert the files

The Fstoppers author notes that the bulk of the workload is in post-processing. Negative Lab Pro handles conversion inside Lightroom, and its scanning guide says lens flare during capture can cause orange blotches and strange color casts.

Will it be sharp enough?

The Library of Congress rounds a 35 mm negative to 1 in on the short side and says an 8 x 10 in print at 300 ppi needs about 2,400 pixels on the 8 in side, so about 2,400 ppi. As an assumed example, not a camera spec, suppose the frame’s short side fills 4,000 pixels of your sensor: 4,000 pixels / 1 in = about 4,000 ppi, above that figure. Check what your setup fills.

Common mistakes

  • Auto exposure. It changes frame to frame; keep one exposure for the roll.
  • Film resting directly on the light pad.
  • Shooting JPEG, which the plugin’s guide says distorts color on inversion.

This route needs no scanner. For a full archive, compare dedicated film scanners in best film scanners, or read how to scan negatives and how to scan slides and negatives. File choices are covered in TIFF vs JPEG scanning, and the scanners category lists the rest.

Changelog: November 2026: first published.